Continuous monitoring of solar panel performance is essential to ensure effective and efficient generation of electrical energy. Developing a monitoring system such as an I-V characteristic curve tracker enables real-time monitoring and identification of potential problems or efficiency improvements. The system utilizes a circuit switching system for accurate and continuous measurement, providi…
Continuous monitoring of solar panel performance is essential to ensure effective and efficient generation of electrical energy. Developing a monitoring system such as an I-V characteristic curve tracker enables real-time monitoring and identification of potential problems or efficiency improvements. The system utilizes a circuit switching system for accurate and continuous measurement, providi…
Studi ini dimaksudkan untuk mengkaji pengembangkan desain kumparan motor induksi 3-fasa dengan desain lilitan mengacu kepada desain lilitan dengan jumlah fasa yang lebih banyak dari 3 fasa. Khusus untuk studi kali ini lebih difokuskan kepada desain kumparan 6 fasa yang diterapkan pada motor induksi 3-fasa tetapi arah fluks yang dihasilkan motor dibuat untuk menghasilkan 5 medan fluks yang berbe…
This research is motivated by the current fact that the availability of energy sources on the earth continues to increase and the demand for energy continues to increase in line with the increasing demand for energy on earth. population growth. So the use of new renewable energy sources and environmentally sound is needed. This study aims to determine the voltage generated using used battery ca…
Single-phase induction (asynchronous) motors are widely used at home. These motors have two windings and usually operate at a lower performance than 3-phase asynchronous motors which have three windings. For this reason, this study aims to design a new winding of a single-phase asynchronous motor by increasing the number of phases in the motor windings in order to increase the performance of th…
The number of lightning stroke on the tower of the 150 kV Koto Panjang-Payakumbuh transmission line located the rocky area has been observed. The high value of tower footing resistance indicates the occurrence of the back-flashover in the transmission line at intensity of 74%. The back-flashover occurrence is dominantly triggered by the tower footing resistance value. Also, the rate of back-fla…
Lightning is a natural phenomenon that destroys a power line. According to the Sumatra load supplier and handling Center (Sumatera P3B), the intensity the number of lightning strikes on a 150 kV transmission line was very high in Indonesia, reaching 66%. As a result, the isokeraunik level on the 150 kV transmission line in that area is at 174 days/year, and the flashover occurrence rate in its …
- Generator Sinkron - Motor Sinkron - Motor Induksi 3- Fasa - Pengenalan motor Induksi 1
Buku Mesin listrik arus listrik edisi revisi ini berisikan teori dasar tentang mesin-mesin listrik arus bolak-balik yang mencakup generator sinkron, motor sinkron, dan motor induksi. Selain itu, buku ini juga berisikan tambahan hasil penelitian penulis tentang pengembangan motor induksi.
Buku Mesin listrik arus listrik ini berisikan teori dasar tentang mesin-mesin listrik arus bolak-balik yang mencakup generator sinkron, motor sinkron, dan motor induksi. Selain itu, buku ini juga berisikan tambahan hasil penelitian penulis tentang pengembangan motor induksi.